Product selection

Search Result69items

c12300-321 product photo

X-ray TDI camera: C12300-321

  • High speed readout
  • Horizontal chassis
  • Bidirectional scanning operation

Evolutional high speed scanning with TDI technology. Bidirectional scanning operation is supported.

  • Effective X-ray tube voltage range
    Approx. 25 kV to 130 kV
  • Detection width
    221.1 mm
  • Effective no. of pixels
    4608 (H)
  • Line speed
    Max. 86.4 m/min
S12497

Si photodiode: S12497

A scintillator can be mounted directly on the chip. photosensitive area: 9.5 x 9.5 mm

  • Photosensitive area
    9.5 × 9.5 mm
  • Spectral response range
    400 to 1100 nm
  • Photosensitivity (typ.)
    0.57 A/W
  • Line speed
    Max. 86.4 m/min
S12498

Si photodiode: S12498

A scintillator can be mounted directly on the chip. photosensitive area: 6.0 x 6.0 mm

  • Photosensitive area
    6.0 × 6.0 mm
  • Spectral response range
    400 to 1100 nm
  • Photosensitivity (typ.)
    0.57 A/W
  • Line speed
    Max. 86.4 m/min
S8984-02

CCD area image sensor: S8984-02

Front-illuminated FFT-CCD for X-ray imaging with 2 mega pixels

  • Photosensitive area
    6.0 × 6.0 mm
  • Spectral response range
    400 to 1100 nm
  • Photosensitivity (typ.)
    0.57 A/W
  • Line speed
    Max. 86.4 m/min
S11865-128G,S11865-64G,etc

Photodiode array with amplifier: S11865-128G

Integrating photodiode array and signal processing circuit into a same package

  • Number of effective pixels
    128 pixels
  • Pixel size
    0.3 x 0.6 mm
  • Note
    for X-ray
  • Line speed
    Max. 86.4 m/min
S11865-256G,S8865-256G

Photodiode array with amplifier: S11865-256G

Integrating photodiode array and signal processing circuit into a same package

  • Number of effective pixels
    256 pixels
  • Pixel size
    0.1 x 0.3 mm
  • Note
    for X-ray
  • Line speed
    Max. 86.4 m/min
S11865-128G,S11865-64G,etc

Photodiode array with amplifier: S11865-64G

Integrating photodiode array and signal processing circuit into a same package

  • Number of effective pixels
    64 pixels
  • Pixel size
    0.7 x 0.8 mm
  • Note
    for X-ray
  • Line speed
    Max. 86.4 m/min
S11866-128G-02,S11866-64G-02,etc

Photodiode array with amplifier: S11866-128G-02

Integrating photodiode array and signal processing circuit into a same package

  • Number of effective pixels
    128 pixels
  • Pixel size
    0.7 x 0.8 mm
  • Note
    for X-ray
  • Line speed
    Max. 86.4 m/min
S11866-128G-02,S11866-64G-02,etc

Photodiode array with amplifier: S11866-64G-02

Integrating photodiode array and signal processing circuit into a same package

  • Number of effective pixels
    64 pixels
  • Pixel size
    1.5 x 1.6 mm
  • Note
    for X-ray
  • Line speed
    Max. 86.4 m/min
C7942CA-22,C7943CA-22

Flat panel sensor: C7942CA-22

120 x 120 mm sensitive area with aluminium window

  • Photosensitive area
    120 x 120 mm
  • Pixel size
    50 x 50 μm
  • Number of total pixels
    2400 x 2400 pixels
  • Line speed
    Max. 86.4 m/min
c8000-30d product photo

X-ray Direct CCD camera: C8000-30D

  • Digital CCD
  • For X-ray

High speed X-ray direct CCD (without scintillator) cameras with 31.4 frames per second frame rate through Camera Link computer interface. It detects EUV and soft X ray (20eV to 10keV).

  • Effective no. of pixels
    640 (H)×480 (V)
  • Readout speed
    31.4 frames/s
  • Readout noise
    100 electrons
  • Dynamic range
    --
c9750-05fcn product photo

X-ray line scan camera: C9750-05FCN

  • RS-422

X-ray line scan camera with detection width of 256mm and line speed from 4m to 100m/minute. It is good for nondestructive testing of objects on belt conveyers.

  • Effective X-ray tube voltage range
    Approx. 25 kV to 160 kV
  • Detection width
    256 mm
  • Effective no. of pixels
    640 pixels
  • Line speed
    4 m/min to 100 m/min
c9750-10tcn product photo

X-ray line scan camera: C9750-05FCN-C

  • Camera Lin

X-ray line scan camera with detection width of 256mm and line speed from 4m to 100m/minute. It is good for nondestructive testing of objects on belt conveyers.

  • Effective X-ray tube voltage range
    Approx. 25 kV to 160 kV
  • Detection width
    256 mm
  • Effective no. of pixels
    640 pixels
  • Line speed
    4 m/min to 100 m/min
c9750-10fcn product photo

X-ray line scan camera: C9750-10FCN

  • RS-422

X-ray line scan camera with detection width of 512mm and line speed from 4m to 100m/minute. It is good for nondestructive testing of objects on belt conveyers.

  • Effective X-ray tube voltage range
    Approx. 25 kV to 160 kV
  • Detection width
    512 mm
  • Effective no. of pixels
    1280 pixels
  • Line speed
    4 m/min to 100 m/min
c9750-20tcn product photo

X-ray line scan camera: C9750-10FCN-C

  • Camera Link

X-ray line scan camera with detection width of 512mm and line speed from 4m to 100m/minute. It is good for nondestructive testing of objects on belt conveyers.

  • Effective X-ray tube voltage range
    Approx. 25 kV to 160 kV
  • Detection width
    512 mm
  • Effective no. of pixels
    1280 pixels
  • Line speed
    4 m/min to 100 m/min
c10650-221 product photo

X-ray TDI camera: C10650-221

  • Horizontal chassis

X-ray TDI camera is useful for in-line applications requiring high-speed operation with high sensitivity. (Standard type)

  • Effective X-ray tube voltage range
    Approx. 25 kV to 90 kV
  • Detection width
    145.9 mm
  • Effective no. of pixels
    3040 (H)
  • Line speed
    Max. 10.702 m/min
c10650-261 product photo

X-ray TDI camera: C10650-261

  • Horizontal chassis
  • Overlap type

X-ray TDI camera is useful for in-line applications requiring high-speed operation with high sensitivity.

  • Effective X-ray tube voltage range
    Approx. 25 kV to 90 kV
  • Detection width
    146.9 mm
  • Effective no. of pixels
    3072 (H)
  • Line speed
    Max. 10.702 m/min
c10650-261v product photo

X-ray TDI camera: C10650-261V

  • Vertical chassis
  • Overlap type

X-ray TDI camera is useful for in-line applications requiring high-speed operation with high sensitivity.

  • Effective X-ray tube voltage range
    Approx. 25 kV to 90 kV
  • Detection width
    146.9 mm
  • Effective no. of pixels
    3072 (H)
  • Line speed
    Max. 10.702 m/min
c10650-261w product photo

X-ray TDI camera: C10650-261W

  • Vertical chassis
  • Overlap type
  • 2 cameras output

X-ray TDI camera is useful for in-line applications requiring high-speed operation with high sensitivity.

  • Effective X-ray tube voltage range
    Approx. 25 kV to 90 kV
  • Detection width
    439.9 mm
  • Effective no. of pixels
    91216 (H)
  • Line speed
    Max. 10.702 m/min
c10650-221 product photo

X-ray TDI camera: C10650-321

  • Horizontal chassis

X-ray TDI camera is useful for in-line applications requiring high-speed operation with high sensitivity. (Standard type)

  • Effective X-ray tube voltage range
    Approx. 25 kV to 90 kV
  • Detection width
    221.1 mm
  • Effective no. of pixels
    4608 (H)
  • Line speed
    Max. 10.702 m/min
c10650-261 product photo

X-ray TDI camera: C10650-361

  • Horizontal chassis
  • Overlap type

X-ray TDI camera is useful for in-line applications requiring high-speed operation with high sensitivity.

  • Effective X-ray tube voltage range
    Approx. 25 kV to 90 kV
  • Detection width
    220.2 mm
  • Effective no. of pixels
    4608 (H)
  • Line speed
    Max. 10.702 m/min
c10650-261v product photo

X-ray TDI camera: C10650-361V

  • Vertical chassis
  • Overlap type

X-ray TDI camera is useful for in-line applications requiring high-speed operation with high sensitivity.

  • Effective X-ray tube voltage range
    Approx. 25 kV to 90 kV
  • Detection width
    220.2 mm
  • Effective no. of pixels
    4608 (H)
  • Line speed
    Max. 10.702 m/min
c10650-261w product photo

X-ray TDI camera: C10650-361W

  • Vertical chassis
  • Overlap type
  • 2 cameras output

X-ray TDI camera is useful for in-line applications requiring high-speed operation with high sensitivity.

  • Effective X-ray tube voltage range
    Approx. 25 kV to 90 kV
  • Detection width
    513.2 mm
  • Effective no. of pixels
    10752 (H)
  • Line speed
    Max. 10.702 m/min
c10650-261 product photo

X-ray TDI camera: C10650-461

  • Horizontal chassis
  • Overlap type

X-ray TDI camera is useful for in-line applications requiring high-speed operation with high sensitivity.

  • Effective X-ray tube voltage range
    Approx. 25 kV to 90 kV
  • Detection width
    293.4 mm
  • Effective no. of pixels
    6144 (H)
  • Line speed
    Max. 10.702 m/min
c10650-261v product photo

X-ray TDI camera: C10650-461V

  • Vertical chassis
  • Overlap type

X-ray TDI camera is useful for in-line applications requiring high-speed operation with high sensitivity.

  • Effective X-ray tube voltage range
    Approx. 25 kV to 90 kV
  • Detection width
    293.4 mm
  • Effective no. of pixels
    6144 (H)
  • Line speed
    Max. 10.702 m/min
c10650-261w product photo

X-ray TDI camera: C10650-461W

  • Vertical chassis
  • Overlap type
  • 2 cameras output

X-ray TDI camera is useful for in-line applications requiring high-speed operation with high sensitivity.

  • Effective X-ray tube voltage range
    Approx. 25 kV to 90 kV
  • Detection width
    586.4 mm
  • Effective no. of pixels
    12288 (H)
  • Line speed
    Max. 10.702 m/min
c10800-04ech product photo

Dual energy X-ray line scan camera: C10800-04ECH

  • High X-ray energy range

Dual energy X-ray line scan camera to realize segregation of different materials. It has 0.8 mm detection pitch and sensitivity from 100 kV to 160 kV).

  • Effective X-ray tube voltage range
    Approx. 100 kV to 160 kV
  • Detection width
    409.6 mm
  • Effective no. of pixels
    1024
  • Line speed
    8 m/min to 200 m/min
c10800-04ech product photo

Dual energy X-ray line scan camera: C10800-04ECM

  • Middle X-ray energy range

Dual energy X-ray line scan camera to realize segregation of different materials. It has 0.8 mm detection pitch and sensitivity from 50 kV to 110 kV).

  • Effective X-ray tube voltage range
    Approx. 50 kV to 110 kV
  • Detection width
    409.6 mm
  • Effective no. of pixels
    1024
  • Line speed
    8 m/min to 200 m/min
c10800-04ech product photo

Dual energy X-ray line scan camera: C10800-08FCM

  • Middle X-ray energy range

Dual energy X-ray line scan camera to realize segregation of different materials. It has 0.4 mm detection pitch and sensitivity from 50 kV to 110 kV).

  • Effective X-ray tube voltage range
    Approx. 50 kV to 110 kV
  • Detection width
    409.6 mm
  • Effective no. of pixels
    2048
  • Line speed
    4 m/min to 100 m/min
c10650-221 product photo

X-ray TDI camera: C12200-321

  • Horizontal chassis
  • Overlap type
  • High speed readout

X-ray TDI camera is useful for in-line applications requiring high-speed operation with high sensitivity.

  • Effective X-ray tube voltage range
    Approx. 25 kV to 90 kV
  • Detection width
    221.1 mm
  • Effective no. of pixels
    4608 (H)
  • Line speed
    Max. 36.864 m/min
c10650-261 product photo

X-ray TDI camera: C12200-461

  • Horizontal chassis
  • Overlap type
  • High speed readout

X-ray TDI camera is useful for in-line applications requiring high-speed operation with high sensitivity.

  • Effective X-ray tube voltage range
    Approx. 25 kV to 90 kV
  • Detection width
    293.4 mm
  • Effective no. of pixels
    6144 (H)
  • Line speed
    Max. 36.864 m/min
c12849 product photo

X-ray sCMOS Camera: C12849-101U

  • For X-ray

High resolution and high sensitivity X-ray sCMOS camera. (Scintillators: Gadox 10μm) Also the product is compact that is suitable as embedded devices for Micro CT/Nano CT system.

  • Effective no. of pixels
    2048 (H)×2048 (V)
  • Readout speed
    30 frames/s
  • Readout noise
    2.3 electrons
  • Dynamic range
    18 000:1
c12849 product photo

X-ray sCMOS Camera: C12849-102U

  • For X-ray

High resolution and high sensitivity X-ray sCMOS camera. (Scintillators: Gadox 20μm) Also the product is compact that is suitable as embedded devices for Micro CT/Nano CT system.

  • Effective no. of pixels
    2048 (H)×2048 (V)
  • Readout speed
    30 frames/s
  • Readout noise
    2.3 electrons
  • Dynamic range
    18 000:1

FOS: J6671

  • FOP with CsI Scintillator

  • Outer Dimension
    30.5 x 21 mm
  • Effective Area
    27 x 17 mm
  • CsI Thickness
    150 μm
  • Dynamic range
    18 000:1

FOS: J6671-01

  • FOP with CsI Scintillator

  • Outer Dimension
    30.5 x 21 mm
  • Effective Area
    27 x 17 mm
  • CsI Thickness
    150 μm
  • Dynamic range
    18 000:1

FOS: J6673

  • FOP with CsI Scintillator

  • Outer Dimension
    50 x 10 mm
  • Effective Area
    47 x 7 mm
  • CsI Thickness
    150 μm
  • Dynamic range
    18 000:1

FOS: J6673-01

  • FOP with CsI Scintillator

  • Outer Dimension
    50 x 10 mm
  • Effective Area
    47 x 7 mm
  • CsI Thickness
    150 μm
  • Dynamic range
    18 000:1

FOS: J6675

  • FOP with CsI Scintillator

  • Outer Dimension
    18 x 18 mm
  • Effective Area
    15 x 15 mm
  • CsI Thickness
    150 μm
  • Dynamic range
    18 000:1

FOS: J6675-01

  • FOP with CsI Scintillator

  • Outer Dimension
    18 x 18 mm
  • Effective Area
    15 x 15 mm
  • CsI Thickness
    150 μm
  • Dynamic range
    18 000:1

FOS: J6677

  • FOP with CsI Scintillator

  • Outer Dimension
    50 x 50 mm
  • Effective Area
    47 x 47 mm
  • CsI Thickness
    150 μm
  • Dynamic range
    18 000:1

FOS: J6677-01

  • FOP with CsI Scintillator

  • Outer Dimension
    50 x 50 mm
  • Effective Area
    47 x 47 mm
  • CsI Thickness
    150 μm
  • Dynamic range
    18 000:1

FOS: J6679

  • FOP with CsI Scintillator

  • Outer Dimension
    Dia. 26.5 mm
  • Effective Area
    Dia. 23.5 mm
  • CsI Thickness
    150 μm
  • Dynamic range
    18 000:1

FOS: J6679-01

  • FOP with CsI Scintillator

  • Outer Dimension
    Dia. 26.5 mm
  • Effective Area
    Dia. 23.5 mm
  • CsI Thickness
    150 μm
  • Dynamic range
    18 000:1

Microfocus X-ray source: L9181-02

Tube voltage : 40 to 130 kV, Maximum output : 39 W, X-ray focal spot size : 5 um, Serial port control : RS-232C

  • Outer Dimension
    Dia. 26.5 mm
  • Effective Area
    Dia. 23.5 mm
  • CsI Thickness
    150 μm
  • Dynamic range
    18 000:1

Microfocus X-ray source: L9181-05

Compared with ordinary L9181-02 (X-ray Beam Angle:45 degrees), L9181-05 has an wide X-ray Beam Angle of 100 degrees.

  • Outer Dimension
    Dia. 26.5 mm
  • Effective Area
    Dia. 23.5 mm
  • CsI Thickness
    150 μm
  • Dynamic range
    18 000:1

Microfocus X-ray source: L9421-02

Tube voltage : 20 to 90 kV, Tube current : 0 to 200 uA, Maximum output : 8 W, X-ray focal spot size : 5 um, Serial port control : RS-232C

  • Outer Dimension
    Dia. 26.5 mm
  • Effective Area
    Dia. 23.5 mm
  • CsI Thickness
    150 μm
  • Dynamic range
    18 000:1

Microfocus X-ray source: L9631

Tube voltage : 40 to 110 kV, Tube current : 10 to 800 uA, Maximum output : 50 W, X-ray focal spot size : 15 to 80 um, Serial port control : RS-232C

  • Outer Dimension
    Dia. 26.5 mm
  • Effective Area
    Dia. 23.5 mm
  • CsI Thickness
    150 μm
  • Dynamic range
    18 000:1

Microfocus X-ray source: L10101

Tube voltage : 40 to 100 kV, Maximum output : 20 W, X-ray focal spot size : 5 um, Short FOD : 6.8 mm, Serial port control : RS-232C

  • Outer Dimension
    Dia. 26.5 mm
  • Effective Area
    Dia. 23.5 mm
  • CsI Thickness
    150 μm
  • Dynamic range
    18 000:1

Microfocus x-ray source: L10321

Tube voltage : 40 to 100 kV, Maximum output : 20 W, X-ray focal spot size : 5 um, Short FOD : 7.3 mm, Serial port control : RS-232C

  • Outer Dimension
    Dia. 26.5 mm
  • Effective Area
    Dia. 23.5 mm
  • CsI Thickness
    150 μm
  • Dynamic range
    18 000:1

Microfocus X-ray source: L10951

Tube voltage : 40 to 110 kV, Tube current : 10 to 800 uA, Maximum output : 50 W, X-ray focal spot size : 15 to 80 um, Serial port control : RS-232C

  • Outer Dimension
    Dia. 26.5 mm
  • Effective Area
    Dia. 23.5 mm
  • CsI Thickness
    150 μm
  • Dynamic range
    18 000:1

Microfocus X-ray source: L12161-07

Tube voltage : 40 to 150 kV, Maximum output : 75 W, X-ray focal spot size : 5 um (at 4 W), Serial port control : RS-232C

  • Outer Dimension
    Dia. 26.5 mm
  • Effective Area
    Dia. 23.5 mm
  • CsI Thickness
    150 μm
  • Dynamic range
    18 000:1
S7199-01

CCD area image sensor: S7199-01

Image sensor with a long, narrow photosensitive area for X-ray imaging (FOS type)

  • Outer Dimension
    Dia. 26.5 mm
  • Effective Area
    Dia. 23.5 mm
  • CsI Thickness
    150 μm
  • Dynamic range
    18 000:1
S7199-01F

CCD area image sensor: S7199-01F

Image sensor with a long, narrow photosensitive area for X-ray imaging (FOP type, without scintillator)

  • Outer Dimension
    Dia. 26.5 mm
  • Effective Area
    Dia. 23.5 mm
  • CsI Thickness
    150 μm
  • Dynamic range
    18 000:1
S8658-01

CCD area image sensor: S8658-01

Image sensor with a long, narrow photosensitive area for X-ray imaging (FOP type)

  • Outer Dimension
    Dia. 26.5 mm
  • Effective Area
    Dia. 23.5 mm
  • CsI Thickness
    150 μm
  • Dynamic range
    18 000:1
S8658-01F

CCD area image sensor: S8658-01F

Imagesensor with a long, narrow photosensitive area (FOP type, without scintillator)

  • Outer Dimension
    Dia. 26.5 mm
  • Effective Area
    Dia. 23.5 mm
  • CsI Thickness
    150 μm
  • Dynamic range
    18 000:1
S11212-021

16-element Si photodiode array: S11212-021

Back-illuminated photodiode arrays for X-ray non-destructive inspection

  • Number of elements
    16
  • Element size (per 1 element)
    1.175 × 2.0 mm
  • Scintillator type
    None
  • Dynamic range
    18 000:1
S11212-121

16-element Si photodiode array: S11212-121

Back-illuminated photodiode array for X-ray non-destructive inspection, with CsI(Tl) scintillator

  • Number of elements
    16
  • Element size (per 1 element)
    1.175 × 2.0 mm
  • Scintillator type
    CsI(Tl)
  • Dynamic range
    18 000:1
S11212-321

16-element Si photodiode array: S11212-321

Back-illuminated photodiode array for X-ray non-destructive inspection, with GOS ceramic scintillator

  • Number of elements
    16
  • Element size (per 1 element)
    1.175 × 2.0 mm
  • Scintillator type
    GOS ceramic
  • Dynamic range
    18 000:1
S11212-421

16-element Si photodiode array: S11212-421

Back-illuminated photodiode array for X-ray non-destructive inspection, with phosphor sheet

  • Number of elements
    16
  • Element size (per 1 element)
    1.175 × 2.0 mm
  • Scintillator type
    Phosphor sheet
  • Dynamic range
    18 000:1
S11299-021

16-element Si photodiode array: S11299-021

Back-illuminated photodiode array for X-ray non-destructive inspection

  • Number of elements
    16
  • Element size (per 1 element)
    1.175 × 2.0 mm
  • Scintillator type
    None
  • Dynamic range
    18 000:1
S11299-121

16-element Si photodiode array: S11299-121

Back-illuminated photodiode array for X-ray non-destructive inspection, with CsI(Tl) scintillator

  • Number of elements
    16
  • Element size (per 1 element)
    1.175 × 2.0 mm
  • Scintillator type
    CsI(Tl)
  • Dynamic range
    18 000:1
S11299-321

16-element Si photodiode array: S11299-321

Back-illuminated photodiode array for X-ray non-destructive inspection, with GOS ceramic scintillator

  • Number of elements
    16
  • Element size (per 1 element)
    1.175 × 2.0 mm
  • Scintillator type
    GOS ceramic
  • Dynamic range
    18 000:1
S11299-421

16-element Si photodiode array: S11299-421

Back-illuminated photodiode array for X-ray non-destructive inspection, with phosphor sheet

  • Number of elements
    16
  • Element size (per 1 element)
    1.175 × 2.0 mm
  • Scintillator type
    Phosphor sheet
  • Dynamic range
    18 000:1
S12858-122

16-element Si photodiode array: S12858-122

Back-illuminated photodiode array for X-ray non-destructive inspection (element pitch: 1.17 mm), with CsI(Tl) scintillator

  • Number of elements
    16
  • Element size (per 1 element)
    0.77 × 2.5 mm
  • Scintillator type
    CsI(Tl)
  • Dynamic range
    18 000:1
S12858-324

16-element Si photodiode array: S12858-324

Back-illuminated photodiode array for X-ray non-destructive inspection (element pitch: 1.17 mm), with GOS ceramic scintillator

  • Number of elements
    16
  • Element size (per 1 element)
    0.77 × 2.5 mm
  • Scintillator type
    GOS ceramic
  • Dynamic range
    18 000:1
S12858-422

16-element Si photodiode array: S12858-422

Back-illuminated photodiode array for X-ray non-destructive inspection (element pitch: 1.17 mm), with phosphor sheet

  • Number of elements
    16
  • Element size (per 1 element)
    0.77 × 2.5 mm
  • Scintillator type
    Phosphor sheet
  • Dynamic range
    18 000:1
S12859-122

16-element Si photodiode array: S12859-122

Back-illuminated photodiode array for X-ray non-destructive inspection (element pitch: 1.17 mm), with CsI(Tl) scintillator

  • Number of elements
    16
  • Element size (per 1 element)
    0.77 × 2.5 mm
  • Scintillator type
    CsI(Tl)
  • Dynamic range
    18 000:1
S12859-324

16-element Si photodiode array: S12859-324

Back-illuminated photodiode array for X-ray non-destructive inspection (element pitch: 1.17 mm), with GOS ceramic scintillator

  • Number of elements
    16
  • Element size (per 1 element)
    0.77 × 2.5 mm
  • Scintillator type
    GOS ceramic
  • Dynamic range
    18 000:1
S12859-422

16-element Si photodiode array: S12859-422

Back-illuminated photodiode array for X-ray non-destructive inspection (element pitch: 1.17 mm), with phosphor sheet

  • Number of elements
    16
  • Element size (per 1 element)
    0.77 × 2.5 mm
  • Scintillator type
    Phosphor sheet
  • Dynamic range
    18 000:1
Scroll to Top